NonDestructive Testing

P8100 Foundation Pile Dynamic Detectors 

Download:
P8100 analysis software

P8100 (Waterproof; Shock and Dirt resistant; higher definitions)

*Using the reflected wave method, the apparatus is used to assess the integrality of concrete pile and identify the extent and location of the pile defect. It can be used for testing perfusion pile and hammer pile. It can also be used for testing the exposed top surface of constructions such as pillars. Realtime on site testing wave can be treated with smoothing, differential, filtering, power exponent and linear amplification methods. Dual-channel sampling with multi-directional testing for target pile increase the efficiency.

P8100 Specifications Enclosure: meets IP65

Items

Specifications

Control Mode

A8 embedded platform, WinCE

Monitor

5.7 inchhigh brightnessTFT Color LCD

Data storage

Built in≥4GB

Operating

Button + Touch screen

A/D Resolution

24 bit A/D

Time Resolution

1µs

Sentinel magnify (time)

125102050100X  

7 scopes adjustable

Sampling time intervals

1µs64ms adjustable

Max length of storage

4096

Input Impedance

≥200KΩ

Dynamic range

≥184 dB

Amplifier frequency range (Hz)

10Hz10kHz

Max length of sampling

4096

Amplitude nonlinear degree

≤1%

Time tolerance

≤0.1%

Gain error

≤1% or ≤0.2 dB

Continuous operating hours

>5 hrs

Channels

2

Consistency of phase position of two channels

≤±1° or ≤0.01ms

Amplitude consistency of two channels

≤1% or ≤0.2dB

Interference between channels

≤0.1%

Transducer sensitivity (acceleration mode)

≥100 mV/g

Frequency range of Transducer (acceleration mode)

0.5 Hz ~9000 Hz

Ports

USB*2

Location

GPS

Data transmission

Via Wi-Fi


Subscribe to Latest NewsSubscribe to Latest News Subscribe to Merchandise NewsSubscribe to Merchandise News  